Description

NYM-J      NYM-O

nymcalidadtotal

Description


These cables are suitable for industrial use, household use and wiring.
Made in accordance with VDE 0250-204

These cables can be used over and under plaster, masonry and concrete. The cables must not come in direct contact with concrete. Their use in open air is only possible as long as the cable is protected against direct sunlight. They can be used in dry, damp or wet environments.

 

Applications
  • Suitable for the following installations:
  • Internal or receptive installations.
  • Internal installations for houses and premises
  • Installations in premises with special characteristics
  • Installations with special purposes: building work provisional and temporary installations
  • Receiver installations
  • Electrical installations on furniture
domestico.gif electrodomestico.gif

vdelogo

Technical Characteristics

NYM-J      NYM-O

nymconstruccion nymdetalle

 

1. Conductor

Rigid electrolyte copper (Class I-II) in accordance with DIN VDE 0295, UNE-EN 60228, EN 60228 and IEC 60228

2. Insulation

PVC type TI-1 in accordance with DIN VDE 0281-1, UNE 21031-4 and HD 21.4S2:1990 and IEC227-4:1979 MOD
3. Filling PVC

4. Cover

PVC type TM-1 in accordance with DIN VDE 0281-1, UNE 21031-4 and HD 21.4S2:1990 and IEC227-4:1979 MOD

Nominal voltage

300/500V

Test voltage

2.000V in C.A.

Maximum temperature

70ºC

Other characteristics

  • Made in accordance with VDE 0250-204
  • Colours in accordance with DIN VDE 0293-308, UNE 21089 and HD 186S2
  • No flame propagation in accordance with VDE 0482-332-1-2, UNE-EN 60332-1, EN 60332-1 and IEC 60332
  • PVC with low emission of hydrochloric acid (HCL)
  • NYM-J cables are made with a yellow/green conductor
  • NYM-O cables are made without yellow/green conductor

 

Dimensions

NYM-J      NYM-O

 

Section (mm2)

Resistance at 20ºC (Ω/Km)

External diameter (mm)

Weight (kg/km)

1x1,5 RE

12,10

5,40

50

1x2,5 RE

7,4

6,00

60

1x4 RE

4,61

6,60

85

1x6 RE

3,08

7,20

105

1x10 RE

1,83

8,50

160

1x16 RM

1,15

9,70

220

2x1,5 RE

12,10

8,80

110

2x2,5 RE

7,41

10,00

155

3x1,5 RE

12,10

8,40

120

3x2,5 RE

7,41

9,60

170

3x4 RE

4,61

11,30

250

3x6 RE

3,08

12,80

335

3x10 RE

1,83

17,00

565

4x1,5 RE

12,10

9,2

150

4x2,5 RE

7,41

10,6

210

4x4 RE

4,61

12,70

315

4x6 RE

3,08

13,80

410

4x10 RE

1,83

17,40

680

4x16 RM

1,15

20,40

970

4x25 RM

0,727

25,20

1.500

4x35 RM

0,524

28,4

2.000

5x1,5 RE

12,10

9,90

175

5x2,5 RE

7,41

11,50

250

5x4 RE

4,61

13,80

370

5x6 RE

3,08

15,00

500

5x10 RE

1,83

19,00

810

5x16 RM

1,15

22,70

1.200

5x25 RM

0,727

27,70

1.800

7x1,5 RE

12,10

11,60

150

7x2,5 RE

7,41

13,70

380

10x1,5 RE

12,10

14,50 365
  • RE: 1 single round conductor wire, class I
  • RM: Multi-conductor round cable, class II

 

Documents